CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION:,310.4 RESIDENTIAL GROUP R-2,,https://up.codes/viewer/texas/ibc-2015/chapter/3/use-and-occupancy-classification#3,,https://up.codes/viewer/texas/ibc-2015/chapter/3/use-and-occupancy-classification#3,
• HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711.",,https://up.codes/viewer/texas/ibc-2015/chapter/4/special-detailed-requirements-based-on-use-and-occupancy#420,,https://up.codes/viewer/texas/ibc-2015/chapter/4/special-detailed-requirements-based-on-use-and-occupancy#420,
CHAPTER 5 CLASSIFICATION OF WORK:,NEW,,https://up.codes/viewer/texas/iebc-2015/chapter/5/classification-of-work#5,,https://up.codes/viewer/texas/iebc-2015/chapter/5/classification-of-work#5,
DWELLING UNIT AND SLEEPING UNIT SEPARATIONS: 1/2HR RATED",,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#708.3,,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#708.3,"EXCEPTIONS:
1. CORRIDOR WALLS PERMITTED TO HAVE A 1/2-HOUR FIRE-RESISTANCE RATING BY TABLE 1020.1.
2. DWELLING UNIT AND SLEEPING UNIT SEPARATIONS IN BUILDINGS OF TYPE IIB, IIIB AND VB CONSTRUCTION SHALL HAVE FIRE-RESISTANCE RATINGS OF NOT LESS THAN 1/2 HOUR IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1."
711.2.4.3 DWELLING UNITS AND SLEEPING UNITS,BETWEEN DWELLING UNITS: 1/2HR RATED,,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#711.2.4.3,,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#711.2.4.3,"EXCEPTION: HORIZONTAL ASSEMBLIES SEPARATING DWELLING UNITS AND SLEEPING UNITS SHALL BE NOT LESS THAN 1/2-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION IN A BUILDING OF TYPE IIB, IIIB AND VB CONSTRUCTION, WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1."
ROOMS AND ENCLOSED: CLASS C",,https://up.codes/viewer/texas/ibc-2015/chapter/8/interior-finishes#803.11,,https://up.codes/viewer/texas/ibc-2015/chapter/8/interior-finishes#803.11,
SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS):,NFPA13 SPRINKLER THROUGHOUT PROJECT (R-2),,https://up.codes/viewer/texas/ibc-2015/chapter/9/fire-protection-systems#903.2.8,,https://up.codes/viewer/texas/ibc-2015/chapter/9/fire-protection-systems#903.2.8,
SEE SECTION 1021 EGRESS BALCONIES FOR CORRIDOR RATING AT EXTERIOR WALL",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1020,,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1020,
SECTION 1021 EGRESS BALCONIES,"EXTERIOR EGRESS BALCONIES SHALL BE SEPARATED FROM THE INTERIOR OF THE BUILDING BY WALLS AND OPENING PROTECTIVES AS REQUIRED FOR CORRIDORS.
SECTION 1020 CORRIDORS 1020.1 CONSTRUCTION
CORRIDORS SHALL BE FIRE-RESISTANCE-RATED IN ACCORDANCE WITH TABLE 1020.1. THE CORRIDOR WALLS REQUIRED TO BE FIRE-RESISTANCE-RATED SHALL COMPLY WITH SECTION 708 FOR FIRE PARTITIONS.
CORRIDORS ADJACENT TO THE EXTERIOR WALLS OF BUILDINGS SHALL BE PERMITTED TO HAVE UNPROTECTED OPENINGS ON UNRATED EXTERIOR WALLS WHERE UNRATED WALLS ARE PERMITTED BY TABLE 602 AND UNPROTECTED OPENINGS ARE PERMITTED BY TABLE 705.8.",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1021.2,,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1021.2,