Column_1,Column_2
Column_1,Column_2,Column_3,Column_4,Column_5,Link,Save
APPLICABLE CODES:,"GENERAL:
• BUILDING/DWELLING CODE IBC 2015 & AHJ AMENDMENTS
EXISTING:
• BUILDING/DWELLING CODE IBC 2015 & BRYAN,TX AMENDMENTS
ENERGY CONSERVATION:
• INTERNATIONAL ENERGY CONSERVATION CODE 2015 & AHJ AMENDMENTS
• INTERNATIONAL ENERGY CONSERVATION CODE 2015 & BRYAN,TX AMENDMENTS
PLUMBING:
• PLUMBING CODE IMC 2015 & BRYAN,TX AMENDMENTS
MECHANICAL:
• MECHANICAL CODE IMC 2015 & AHJ AMENDMENTS
• MECHANICAL CODE IMC 2015 & BRYAN,TX AMENDMENTS
ELECTRICAL:
• ELECTRICAL CODE NEC 2017 & AHJ AMENDMENTS
• ELECTRICAL CODE NEC 2020 & BRYAN,TX AMENDMENTS
FIRE:
• FIRE/LIFE SAFETY CODE 2009 NFPA-1 & AHJ AMENDMENTS
• FIRE/LIFE SAFETY CODE 2009 NFPA-1 & BRYAN,TX AMENDMENTS
ACCESSIBILITY:
• ANSI STANDARD A117.1-2009- FOR ACCESSIBILITY
• FAIR HOUSING ACT
FUEL:
• INTERNATIONAL FUEL GAS CODE 2015 & AHJ AMENDMENTS"
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION:,310.4 RESIDENTIAL GROUP R-2
• INTERNATIONAL FUEL GAS CODE 2015 & BRYAN,TX AMENDMENTS",,,,,"GENERAL:
• BUILDING/DWELLING CODE IBC 2015
• (WI COMMERCIAL BUILDING CODE SPS 362)
EXISTING:
• INTERNATIONAL EXISTING BUILDING CODE 2015
• (WI COMMERCIAL BUILDING CODE SPS 366)
ENERGY CONSERVATION:
• INTERNATIONAL ENERGY CONSERVATION CODE 2015
• (WI COMMERCIAL BUILDING CODE V363)
PLUMBING:
• WI COMMERCIAL BUILDING CODE SPS 381-387
MECHANICAL:
• MECHANICAL CODE IMC 2015
• (WI COMMERCIAL BUILDING CODE SPS 364)
ELECTRICAL:
• ELECTRICAL CODE NEC 2017
• (WI COMMERCIAL BUILDING CODE SPS 316
FIRE:
• FIRE/LIFE SAFETY CODE 2009 NFPA-1
• (WI COMMERCIAL BUILDING CODE SPS 314 & 330)
ACCESSIBILITY:
• ANSI STANDARD A117.1-2009- FOR ACCESSIBILITY
• (WI COMMERCIAL BUILDING CODE SPS 362)
FUEL:
• INTERNATIONAL FUEL GAS CODE 2015
• (WI COMMERCIAL BUILDING CODE CHAPTER 365)"
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION:,310.4 RESIDENTIAL GROUP R-2,,https://up.codes/viewer/texas/ibc-2015/chapter/3/use-and-occupancy-classification#3,,https://up.codes/viewer/texas/ibc-2015/chapter/3/use-and-occupancy-classification#3,
"SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4","SECTION 420 GROUPS R-2
• FIRE PARTITIONS IN ACCORDANCE WITH SECTION 708
• HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711."
CHAPTER 5 CLASSIFICATION OF WORK:,NEW
• HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711.",,https://up.codes/viewer/texas/ibc-2015/chapter/4/special-detailed-requirements-based-on-use-and-occupancy#420,,https://up.codes/viewer/texas/ibc-2015/chapter/4/special-detailed-requirements-based-on-use-and-occupancy#420,
CHAPTER 5 CLASSIFICATION OF WORK:,NEW,,https://up.codes/viewer/texas/iebc-2015/chapter/5/classification-of-work#5,,https://up.codes/viewer/texas/iebc-2015/chapter/5/classification-of-work#5,
504.3 HEIGHT IN FEET,"R-2 TYPE VB (SPRINKLERED):
• ACTUAL: 35FT
• ALLOWED: 60FT
"
",,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.3,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.3,
504.4 NUMBER OF STORIES,"R-2 TYPE VB (SPRINKLERED):
• ACTUAL: 3
• ALLOWED: 4
"
",,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.4,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.4,
"506.2 ALLOWABLE AREA DETERMINATION
&
506.3 FRONTAGE INCREASE:"," • TABULAR PER FLOOR AREA LIMIT PER CHAPTER 5 = 7000 SQ.FT.
@ -46,9 +72,32 @@ CHAPTER 5 CLASSIFICATION OF WORK:,NEW
ACTUAL
• (ALL FLOORS): 16,826SF
• FLOORS: 3"
508.3 NONSEPARATED OCCUPANCIES:,N/A
508.4 SEPARATED OCCUPANCIES,N/A
• FLOORS: 3",,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#506.2,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#506.2,"FACING NORTH:
• 174FT (60FT TO R.O.W)
FACING EAST:
• 145 (60FT TO R.O.W)
FACING SOUTH:
• 73FT (6FT TO P.L.)
• 33FT (117FT TO P.L)
• 73FT (6FT TO P.L.)
FACING WEST:
• 145FT (13FT TO P.L.)
FOR R-2
• ALLOWABLE AREA PER FLOOR: 23,082SF (W/ FRONTAGE INCREASE)
• ACTUAL
• 1ST FLOOR:20,889SF
• 2ND FLOOR:22,879SF
• 3RD FLOOR: 22,957SF
• TOTAL ALLOWABLE AREA:69,246SF
• ACTUAL: 66,725SF
FOR S-2
• TYPE 1B (316,000 W/O FRONTAGE INCREASE)
• ACTUAL: 29,041SF
"
508.3 NONSEPARATED OCCUPANCIES:,N/A,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.3,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.3,
508.4 SEPARATED OCCUPANCIES,N/A,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.4,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.4,
"TABLE 601
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)","FOR TYPE VB
STRUCTURAL FRAME: 0 HR
@ -58,7 +107,7 @@ FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)","FOR TYPE VB
NON-BEARING WALLS-INTERIOR: 0 HR
FLOOR CONSTRUCTION: 0 HR
ROOF CONSTRUCTION: 0 HR
"
",,https://up.codes/viewer/texas/ibc-2015/chapter/6/types-of-construction#601,,https://up.codes/viewer/texas/ibc-2015/chapter/6/types-of-construction#601,
"TABLE 602
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE","TYPE-VB
@ -66,31 +115,35 @@ FIRE SEPARATION DISTANCE
• X < 5C = 1 HR
• 5 ≤ X ≤ 10 = 1 HR
• 10 ≤ X ≤ 30 = 0 HR
• X ≥ 30 = 0 HR"
• X ≥ 30 = 0 HR",,,,,
708.3 FIRE-RESISTANCE RATING,"CORRIDORS: 1/2HR RATED
DWELLING UNIT AND SLEEPING UNIT SEPARATIONS: 1/2HR RATED"
711.2.4.3 DWELLING UNITS AND SLEEPING UNITS,BETWEEN DWELLING UNITS: 1/2HR RATED
DWELLING UNIT AND SLEEPING UNIT SEPARATIONS: 1/2HR RATED",,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#708.3,,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#708.3,"EXCEPTIONS:
1. CORRIDOR WALLS PERMITTED TO HAVE A 1/2-HOUR FIRE-RESISTANCE RATING BY TABLE 1020.1.
2. DWELLING UNIT AND SLEEPING UNIT SEPARATIONS IN BUILDINGS OF TYPE IIB, IIIB AND VB CONSTRUCTION SHALL HAVE FIRE-RESISTANCE RATINGS OF NOT LESS THAN 1/2 HOUR IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1."
711.2.4.3 DWELLING UNITS AND SLEEPING UNITS,BETWEEN DWELLING UNITS: 1/2HR RATED,,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#711.2.4.3,,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#711.2.4.3,"EXCEPTION: HORIZONTAL ASSEMBLIES SEPARATING DWELLING UNITS AND SLEEPING UNITS SHALL BE NOT LESS THAN 1/2-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION IN A BUILDING OF TYPE IIB, IIIB AND VB CONSTRUCTION, WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1."
803.11 INTERIOR FINISH REQUIREMENTS BASED ON GROUP,"FOR SPRINKLERED R-2:
INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS: CLASS C
CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS: CLASS C
ROOMS AND ENCLOSED: CLASS C"
SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS):,NFPA13 SPRINKLER THROUGHOUT PROJECT (R-2)
ROOMS AND ENCLOSED: CLASS C",,https://up.codes/viewer/texas/ibc-2015/chapter/8/interior-finishes#803.11,,https://up.codes/viewer/texas/ibc-2015/chapter/8/interior-finishes#803.11,
SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS):,NFPA13 SPRINKLER THROUGHOUT PROJECT (R-2),,https://up.codes/viewer/texas/ibc-2015/chapter/9/fire-protection-systems#903.2.8,,https://up.codes/viewer/texas/ibc-2015/chapter/9/fire-protection-systems#903.2.8,
SECTION 1020 CORRIDORS,"CORRIDORS: 1/2HR RATED
SEE SECTION 1021 EGRESS BALCONIES FOR CORRIDOR RATING AT EXTERIOR WALL"
SEE SECTION 1021 EGRESS BALCONIES FOR CORRIDOR RATING AT EXTERIOR WALL",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1020,,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1020,
SECTION 1004 OCCUPANT LOAD,"TABLE 1004.1.2
MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
RESIDENTIAL: 200 GROSS"
RESIDENTIAL: 200 GROSS",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1004.1.2,,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1004.1.2,
1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE:,"FOR R-2
MAXIMUM COMMON PATH WITH SPRINKLER SYSTEM: 125FT
MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT: 49
"
",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1006.2.1,,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1006.2.1,
SECTION 1017 EXIT ACCESS TRAVEL DISTANCE:,"FOR R-2: 250 (W/SPRINKLER)
"
1020.4 DEAD ENDS:,50FT (WITH NFPA13 SPRINKLERS)
",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1017,,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1017,
1020.4 DEAD ENDS:,50FT (WITH NFPA13 SPRINKLERS),,https://up.codes/viewer/texas/iebc-2015/chapter/8/alterations-level-2#805.6,HTTPS://UP.CODES/VIEWER/TEXAS/IBC-2015/CHAPTER/10/MEANS-OF-EGRESS#1020.4,https://up.codes/viewer/texas/iebc-2015/chapter/8/alterations-level-2#805.6,
SECTION 1021 EGRESS BALCONIES,"EXTERIOR EGRESS BALCONIES SHALL BE SEPARATED FROM THE INTERIOR OF THE BUILDING BY WALLS AND OPENING PROTECTIVES AS REQUIRED FOR CORRIDORS.
SECTION 1020 CORRIDORS 1020.1 CONSTRUCTION
@ -98,7 +151,7 @@ SECTION 1020 CORRIDORS 1020.1 CONSTRUCTION
CORRIDORS SHALL BE FIRE-RESISTANCE-RATED IN ACCORDANCE WITH TABLE 1020.1. THE CORRIDOR WALLS REQUIRED TO BE FIRE-RESISTANCE-RATED SHALL COMPLY WITH SECTION 708 FOR FIRE PARTITIONS.
EXCEPTIONS:
CORRIDORS ADJACENT TO THE EXTERIOR WALLS OF BUILDINGS SHALL BE PERMITTED TO HAVE UNPROTECTED OPENINGS ON UNRATED EXTERIOR WALLS WHERE UNRATED WALLS ARE PERMITTED BY TABLE 602 AND UNPROTECTED OPENINGS ARE PERMITTED BY TABLE 705.8."
CORRIDORS ADJACENT TO THE EXTERIOR WALLS OF BUILDINGS SHALL BE PERMITTED TO HAVE UNPROTECTED OPENINGS ON UNRATED EXTERIOR WALLS WHERE UNRATED WALLS ARE PERMITTED BY TABLE 602 AND UNPROTECTED OPENINGS ARE PERMITTED BY TABLE 705.8.",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1021.2,,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1021.2,
2902.1 MINIMUM NUMBER OF FIXTURES,"CLASSIFICATION & OCCUPANCY:
---
@ -106,4 +159,32 @@ CORRIDORS ADJACENT TO THE EXTERIOR WALLS OF BUILDINGS SHALL BE PERMITTED TO HAVE
R-2
• WATER CLOSETS: 1 PER DWELLING
• LAVATORIES: 1 PER DWELLING
• BATHTUBS/ SHOWERS: 1 PER DWELLING"
• BATHTUBS/ SHOWERS: 1 PER DWELLING",,https://up.codes/viewer/texas/ibc-2015/chapter/29/plumbing-systems#2902.1,,https://up.codes/viewer/texas/ibc-2015/chapter/29/plumbing-systems#2902.1,"CLASSIFICATION & OCCUPANCY:
---
R-2
• WATER CLOSETS: 1 PER DWELLING
• (REQUIRED/PROVIDED) 71/88
• LAVATORIES: 1 PER DWELLING
• (REQUIRED/PROVIDED) 71/88
---
A-2 (44 OCCUPANTS)
• WATER CLOSETS: 1 PER 75
• WOMEN: .29
• MEN: .29
• LAVATORIES: 1 PER 75
• WOMEN: .29
• MEN: .29
"
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,

1 Column_1 Column_2 Column_3 Column_4 Column_5 Link Save
2 APPLICABLE CODES: GENERAL: • BUILDING/DWELLING CODE IBC 2015 & AHJ AMENDMENTS EXISTING: ENERGY CONSERVATION: • INTERNATIONAL ENERGY CONSERVATION CODE 2015 & AHJ AMENDMENTS PLUMBING: MECHANICAL: • MECHANICAL CODE IMC 2015 & AHJ AMENDMENTS ELECTRICAL: • ELECTRICAL CODE NEC 2017 & AHJ AMENDMENTS FIRE: • FIRE/LIFE SAFETY CODE 2009 NFPA-1 & AHJ AMENDMENTS ACCESSIBILITY: • ANSI STANDARD A117.1-2009- FOR ACCESSIBILITY FUEL: • INTERNATIONAL FUEL GAS CODE 2015 & AHJ AMENDMENTS GENERAL: • BUILDING/DWELLING CODE IBC 2015 & BRYAN,TX AMENDMENTS ENERGY CONSERVATION: • INTERNATIONAL ENERGY CONSERVATION CODE 2015 & BRYAN,TX AMENDMENTS PLUMBING: • PLUMBING CODE IMC 2015 & BRYAN,TX AMENDMENTS MECHANICAL: • MECHANICAL CODE IMC 2015 & BRYAN,TX AMENDMENTS ELECTRICAL: • ELECTRICAL CODE NEC 2020 & BRYAN,TX AMENDMENTS FIRE: • FIRE/LIFE SAFETY CODE 2009 NFPA-1 & BRYAN,TX AMENDMENTS ACCESSIBILITY: • ANSI STANDARD A117.1-2009- FOR ACCESSIBILITY • FAIR HOUSING ACT FUEL: • INTERNATIONAL FUEL GAS CODE 2015 & BRYAN,TX AMENDMENTS GENERAL: • BUILDING/DWELLING CODE IBC 2015 • (WI COMMERCIAL BUILDING CODE SPS 362) EXISTING: • INTERNATIONAL EXISTING BUILDING CODE 2015 • (WI COMMERCIAL BUILDING CODE SPS 366) ENERGY CONSERVATION: • INTERNATIONAL ENERGY CONSERVATION CODE 2015 • (WI COMMERCIAL BUILDING CODE V363) PLUMBING: • WI COMMERCIAL BUILDING CODE SPS 381-387 MECHANICAL: • MECHANICAL CODE IMC 2015 • (WI COMMERCIAL BUILDING CODE SPS 364) ELECTRICAL: • ELECTRICAL CODE NEC 2017 • (WI COMMERCIAL BUILDING CODE SPS 316 FIRE: • FIRE/LIFE SAFETY CODE 2009 NFPA-1 • (WI COMMERCIAL BUILDING CODE SPS 314 & 330) ACCESSIBILITY: • ANSI STANDARD A117.1-2009- FOR ACCESSIBILITY • (WI COMMERCIAL BUILDING CODE SPS 362) FUEL: • INTERNATIONAL FUEL GAS CODE 2015 • (WI COMMERCIAL BUILDING CODE CHAPTER 365)
3 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION: 310.4 RESIDENTIAL GROUP R-2 https://up.codes/viewer/texas/ibc-2015/chapter/3/use-and-occupancy-classification#3 https://up.codes/viewer/texas/ibc-2015/chapter/3/use-and-occupancy-classification#3
SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4 SECTION 420 GROUPS R-2 • FIRE PARTITIONS IN ACCORDANCE WITH SECTION 708 • HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711.
4 CHAPTER 5 CLASSIFICATION OF WORK: SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4 NEW SECTION 420 GROUPS R-2 • FIRE PARTITIONS IN ACCORDANCE WITH SECTION 708 • HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711. https://up.codes/viewer/texas/ibc-2015/chapter/4/special-detailed-requirements-based-on-use-and-occupancy#420 https://up.codes/viewer/texas/ibc-2015/chapter/4/special-detailed-requirements-based-on-use-and-occupancy#420
5 504.3 HEIGHT IN FEET CHAPTER 5 CLASSIFICATION OF WORK: R-2 – TYPE VB (SPRINKLERED): • ACTUAL: 35FT • ALLOWED: 60FT NEW https://up.codes/viewer/texas/iebc-2015/chapter/5/classification-of-work#5 https://up.codes/viewer/texas/iebc-2015/chapter/5/classification-of-work#5
6 504.4 NUMBER OF STORIES 504.3 HEIGHT IN FEET R-2 – TYPE VB (SPRINKLERED): • ACTUAL: 3 • ALLOWED: 4 R-2 – TYPE VB (SPRINKLERED): • ACTUAL: 35FT • ALLOWED: 60FT https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.3 https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.3
7 504.4 NUMBER OF STORIES R-2 – TYPE VB (SPRINKLERED): • ACTUAL: 3 • ALLOWED: 4 https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.4 https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.4
8 506.2 ALLOWABLE AREA DETERMINATION & 506.3 FRONTAGE INCREASE: • TABULAR PER FLOOR AREA LIMIT PER CHAPTER 5 = 7000 SQ.FT. • ALLOW HEIGHT = 60 FT; ALLOW STORIES = 3 • NFPA 13 SPRINKLERS • COMPUTE AREA INCREASE DUE TO FRONTAGE: FRONTAGE COEFFICIENT, IF 0.589 • PERIMETER, P 354 FT • 'FRONTAGE' PERIMETER, F 306 FT • WEIGHTED AVERAGE DISTANCE FROM 'F' = 228.75 FT • COMPUTE ALLOWABLE PER STORY AREA, AA = AT +(NS X IF) = 25120.94 SQ.FT. • MAXIMUM ALLOWABLE AREA = AA X 3 = 75362.83 SQ.FT. • MAXIMUM NUMBER OF STORIES FOR GROUP R WITH NFPA 13R SPRINKLERS, PER SEC. 903.3.1.2.THIS CRITERIA IS MET, SO STORY LIMIT = 3 • THE REVISED ALLOWABLE HEIGHT IS 60 FT. ACTUAL • (ALL FLOORS): 16,826SF • FLOORS: 3 https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#506.2 https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#506.2 FACING NORTH: • 174FT (60FT TO R.O.W) FACING EAST: • 145 (60FT TO R.O.W) FACING SOUTH: • 73FT (6FT TO P.L.) • 33FT (117FT TO P.L) • 73FT (6FT TO P.L.) FACING WEST: • 145FT (13FT TO P.L.) FOR R-2 • ALLOWABLE AREA PER FLOOR: 23,082SF (W/ FRONTAGE INCREASE) • ACTUAL • 1ST FLOOR:20,889SF • 2ND FLOOR:22,879SF • 3RD FLOOR: 22,957SF • TOTAL ALLOWABLE AREA:69,246SF • ACTUAL: 66,725SF FOR S-2 • TYPE 1B (316,000 W/O FRONTAGE INCREASE) • ACTUAL: 29,041SF
9 508.3 NONSEPARATED OCCUPANCIES: N/A https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.3 https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.3
10 508.4 SEPARATED OCCUPANCIES N/A https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.4 https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.4
11 TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) FOR TYPE VB STRUCTURAL FRAME: 0 HR BEARING WALLS- EXTERIOR: 0 HR BEARING WALLS-INTERIOR: 0 HR NON-BEARING WALLS-EXTERIOR – (SEE TABLE 602) NON-BEARING WALLS-INTERIOR: 0 HR FLOOR CONSTRUCTION: 0 HR ROOF CONSTRUCTION: 0 HR https://up.codes/viewer/texas/ibc-2015/chapter/6/types-of-construction#601 https://up.codes/viewer/texas/ibc-2015/chapter/6/types-of-construction#601
12 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE TYPE-VB FIRE SEPARATION DISTANCE • X < 5C = 1 HR • 5 ≤ X ≤ 10 = 1 HR • 10 ≤ X ≤ 30 = 0 HR • X ≥ 30 = 0 HR
13 708.3 FIRE-RESISTANCE RATING CORRIDORS: 1/2HR RATED DWELLING UNIT AND SLEEPING UNIT SEPARATIONS: 1/2HR RATED https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#708.3 https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#708.3 EXCEPTIONS: 1. CORRIDOR WALLS PERMITTED TO HAVE A 1/2-HOUR FIRE-RESISTANCE RATING BY TABLE 1020.1. 2. DWELLING UNIT AND SLEEPING UNIT SEPARATIONS IN BUILDINGS OF TYPE IIB, IIIB AND VB CONSTRUCTION SHALL HAVE FIRE-RESISTANCE RATINGS OF NOT LESS THAN 1/2 HOUR IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1.
14 711.2.4.3 DWELLING UNITS AND SLEEPING UNITS BETWEEN DWELLING UNITS: 1/2HR RATED https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#711.2.4.3 https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#711.2.4.3 EXCEPTION: HORIZONTAL ASSEMBLIES SEPARATING DWELLING UNITS AND SLEEPING UNITS SHALL BE NOT LESS THAN 1/2-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION IN A BUILDING OF TYPE IIB, IIIB AND VB CONSTRUCTION, WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1.
15 803.11 INTERIOR FINISH REQUIREMENTS BASED ON GROUP FOR SPRINKLERED R-2: INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS: CLASS C CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS: CLASS C ROOMS AND ENCLOSED: CLASS C https://up.codes/viewer/texas/ibc-2015/chapter/8/interior-finishes#803.11 https://up.codes/viewer/texas/ibc-2015/chapter/8/interior-finishes#803.11
16 SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS): NFPA13 SPRINKLER THROUGHOUT PROJECT (R-2) https://up.codes/viewer/texas/ibc-2015/chapter/9/fire-protection-systems#903.2.8 https://up.codes/viewer/texas/ibc-2015/chapter/9/fire-protection-systems#903.2.8
17 SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS): SECTION 1020 CORRIDORS NFPA13 SPRINKLER THROUGHOUT PROJECT (R-2) CORRIDORS: 1/2HR RATED SEE SECTION 1021 EGRESS BALCONIES FOR CORRIDOR RATING AT EXTERIOR WALL https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1020 https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1020
18 SECTION 1020 CORRIDORS SECTION 1004 OCCUPANT LOAD CORRIDORS: 1/2HR RATED SEE SECTION 1021 EGRESS BALCONIES FOR CORRIDOR RATING AT EXTERIOR WALL TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT RESIDENTIAL: 200 GROSS https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1004.1.2 https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1004.1.2
19 SECTION 1004 OCCUPANT LOAD 1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE: TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT RESIDENTIAL: 200 GROSS FOR R-2 MAXIMUM COMMON PATH WITH SPRINKLER SYSTEM: 125FT MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT: 49 https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1006.2.1 https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1006.2.1
20 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE: FOR R-2: 250 (W/SPRINKLER) https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1017 https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1017
21 1020.4 DEAD ENDS: 50FT (WITH NFPA13 SPRINKLERS) https://up.codes/viewer/texas/iebc-2015/chapter/8/alterations-level-2#805.6 HTTPS://UP.CODES/VIEWER/TEXAS/IBC-2015/CHAPTER/10/MEANS-OF-EGRESS#1020.4 https://up.codes/viewer/texas/iebc-2015/chapter/8/alterations-level-2#805.6
22 SECTION 1021 EGRESS BALCONIES EXTERIOR EGRESS BALCONIES SHALL BE SEPARATED FROM THE INTERIOR OF THE BUILDING BY WALLS AND OPENING PROTECTIVES AS REQUIRED FOR CORRIDORS. SECTION 1020 CORRIDORS 1020.1 CONSTRUCTION CORRIDORS SHALL BE FIRE-RESISTANCE-RATED IN ACCORDANCE WITH TABLE 1020.1. THE CORRIDOR WALLS REQUIRED TO BE FIRE-RESISTANCE-RATED SHALL COMPLY WITH SECTION 708 FOR FIRE PARTITIONS. EXCEPTIONS: CORRIDORS ADJACENT TO THE EXTERIOR WALLS OF BUILDINGS SHALL BE PERMITTED TO HAVE UNPROTECTED OPENINGS ON UNRATED EXTERIOR WALLS WHERE UNRATED WALLS ARE PERMITTED BY TABLE 602 AND UNPROTECTED OPENINGS ARE PERMITTED BY TABLE 705.8. https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1021.2 https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1021.2
23 2902.1 MINIMUM NUMBER OF FIXTURES CLASSIFICATION & OCCUPANCY: --- R-2 • WATER CLOSETS: 1 PER DWELLING • LAVATORIES: 1 PER DWELLING • BATHTUBS/ SHOWERS: 1 PER DWELLING https://up.codes/viewer/texas/ibc-2015/chapter/29/plumbing-systems#2902.1 https://up.codes/viewer/texas/ibc-2015/chapter/29/plumbing-systems#2902.1 CLASSIFICATION & OCCUPANCY: --- R-2 • WATER CLOSETS: 1 PER DWELLING • (REQUIRED/PROVIDED) 71/88 • LAVATORIES: 1 PER DWELLING • (REQUIRED/PROVIDED) 71/88 --- A-2 (44 OCCUPANTS) • WATER CLOSETS: 1 PER 75 • WOMEN: .29 • MEN: .29 • LAVATORIES: 1 PER 75 • WOMEN: .29 • MEN: .29
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
107
108
109
110
111
112
113
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
151
152
153
154
155
156
157
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190

View File

@ -1,84 +1,87 @@
Sheet_Number,Sheet_Name,Sheet_File,Sheet_Last_Issue_Date
G000,COVER,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
G001,CODE & LIFE SAFETY,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
S0.0,TYPICAL GENERAL NOTES,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S0.01,STATEMENT OF SPECIAL INSPECTIONS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S0.1,FOUNDATION PLAN,101_W_33rd_St_Structure.rvt,06/10/22 Issued for Permit
S0.1A,FOUNDATION NOTES AND 3D,101_W_33rd_St_Structure.rvt,06/10/22 Issued for Permit
S0.2,FRAMING PLAN - 2ND FLOOR,101_W_33rd_St_Structure.rvt,06/10/22 Issued for Permit
S0.3,FRAMING PLAN - 3RD FLOOR,101_W_33rd_St_Structure.rvt,06/10/22 Issued for Permit
S0.4,FRAMING PLAN - ROOF,101_W_33rd_St_Structure.rvt,06/10/22 Issued for Permit
S3.0,FOUNDATION DETAILS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S3.1,FOUNDATION DETAILS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S4.0,TYPICAL WOOD FRAMING DETAILS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S4.1,TYPICAL WOOD FRAMING WALL DETAILS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S4.2,TYPICAL WOOD FLOOR TRUSS DETAILS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S4.3,TYPICAL WOOD FRAMING LATERAL DETAILS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S4.4,TYPICAL WOOD ROOF TRUSS DETAILS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
S4.5,TYPICAL STEEL DETAILS,101 W. 33rd Apartments_STR Details,06/10/22 Issued for Permit
A101,FLOOR PLAN - 1ST,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A102,FLOOR PLAN - 2ND,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A103,FLOOR PLAN - 3RD,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A104,FLOOR PLAN - ROOF,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A150,REFLECTED CEILING PLANS,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A200,BUILDING ELEVATION - NORTH/WEST,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A201,BUILDING ELEVATION - SOUTH/EAST,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A300,BUILDING SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A301,BUILDING SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A302,BUILDING SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A303,BUILDING SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A400,WALL SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A401,WALL SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A402,WALL SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A410,STAIR SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A411,STAIR SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A412,STAIR SECTIONS,101_W_33rd_St_Shell.rvt,06/10/22 Issued for Permit
A470,UNIT PLANS - STUDIOS - LONG AND SHORT - (TYPE B ADA UNIT - 1ST FLOOR ONLY),101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A471,UNIT PLANS - (TYPE A ADA UNIT - 1ST FLOOR ONLY),101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A472,UNIT PLANS - 1BD - END UNITS,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A500,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,06/10/22 Issued for Permit
A501,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,06/10/22 Issued for Permit
A502,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,06/10/22 Issued for Permit
A503,LARGE SCALE DETAILS,101_W_33rd_St_Details.rte,06/10/22 Issued for Permit
A504,LARGE SCALE DETAILS,101_W_33rd_St_Details.rte,06/10/22 Issued for Permit
A505,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,06/10/22 Issued for Permit
A506,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,06/10/22 Issued for Permit
A600,SCHEDULES,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A610,WALL -FIRE RATED ASSEMBLY DETAIL -U341,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A611,WALL -FIRE RATED ASSEMBLY DETAIL -U305,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A612,FLOOR -FIRE RATED ASSEMBLY DETAIL -L521,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A613,FLOOR -FIRE RATED ASSEMBLY DETAIL -L521 CONT.,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A614,FIRE STOP DETAILS -FLOOR,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A615,FIRE STOP DETAILS -FLOOR,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A616,FIRE STOP DETAILS -FLOOR,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A617,FIRE STOP DETAILS WALLS,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A751,ADA -TYPE A AND B,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
A800,PARTITION DETAILS - WOOD STUDS,101_W_33rd_St_Units.rvt,06/10/22 Issued for Permit
P100,PLUMBING PLAN TYPICAL UNIT,,06/10/22 Issued for Permit
P101,PLUMBING PLAN 1ST FLOOR,,06/10/22 Issued for Permit
P102,PLUMBING PLAN 2ND FLOOR,,06/10/22 Issued for Permit
P103,PLUMBING PLAN 3RD FLOOR,,06/10/22 Issued for Permit
P104,PLUMBING PLAN ROOF,,06/10/22 Issued for Permit
P200,PLUMBING RISERS,,06/10/22 Issued for Permit
P201,PLUMBING DETAILS,,06/10/22 Issued for Permit
P300,PLUMBING NOTES & SCHEDULES,,06/10/22 Issued for Permit
MEP100,MEP SITE PLAN,,06/10/22 Issued for Permit
MEP101,SITE LIGHTING LEVELS,,06/10/22 Issued for Permit
M100,MECHANICAL PLAN TYPICAL UNIT,,06/10/22 Issued for Permit
M101,MECHANICAL PLAN 1ST FLOOR,,06/10/22 Issued for Permit
M102,MECHANICAL PLAN 2ND FLOOR,,06/10/22 Issued for Permit
M103,MECHANICAL PLAN 3RD FLOOR,,06/10/22 Issued for Permit
M104,MECHANICAL PLAN ROOF,,06/10/22 Issued for Permit
M200,MECHANICAL DETAILS,,06/10/22 Issued for Permit
M300,MECHANICAL NOTES & SCHEDULES,,06/10/22 Issued for Permit
E100,ELECTRICAL POWER PLAN TYPICAL UNIT,,06/10/22 Issued for Permit
E101,ELECTRICAL POWER PLAN 1ST FLOOR,,06/10/22 Issued for Permit
E102,ELECTRICAL POWER PLAN 2ND FLOOR,,06/10/22 Issued for Permit
E103,ELECTRICAL POWER PLAN 3RD FLOOR,,06/10/22 Issued for Permit
E104,ELECTRICAL POWER PLAN ROOF,,06/10/22 Issued for Permit
E120,ELECTRICAL LIGHTING PLAN TYPICAL UNIT,,06/10/22 Issued for Permit
E121,ELECTRICAL LIGHTING PLAN 1ST FLOOR,,06/10/22 Issued for Permit
E122,ELECTRICAL LIGHTING PLAN 2ND & 3RD FLOOR,,06/10/22 Issued for Permit
E200,ELECTRICAL RISER & DETAILS,,06/10/22 Issued for Permit
E201,ELECTRICAL PANEL SCHEDULES,,06/10/22 Issued for Permit
E300,ELECTRICAL NOTES AND SCHEDULES,,06/10/22 Issued for Permit
G000,COVER,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
G001,CODE & LIFE SAFETY,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
G002,CODE & LIFE SAFETY,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
S0.0,TYPICAL GENERAL NOTES,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S0.01,STATEMENT OF SPECIAL INSPECTIONS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S0.1,FOUNDATION PLAN,101_W_33rd_St_Structure.rvt,07/22/22 Permit Revisions
S0.1A,FOUNDATION NOTES AND 3D,101_W_33rd_St_Structure.rvt,07/22/22 Permit Revisions
S0.2,FRAMING PLAN - 2ND FLOOR,101_W_33rd_St_Structure.rvt,07/22/22 Permit Revisions
S0.3,FRAMING PLAN - 3RD FLOOR,101_W_33rd_St_Structure.rvt,07/22/22 Permit Revisions
S0.4,FRAMING PLAN - ROOF,101_W_33rd_St_Structure.rvt,07/22/22 Permit Revisions
S3.0,FOUNDATION DETAILS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S3.1,FOUNDATION DETAILS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S4.0,TYPICAL WOOD FRAMING DETAILS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S4.1,TYPICAL WOOD FRAMING WALL DETAILS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S4.2,TYPICAL WOOD FLOOR TRUSS DETAILS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S4.3,TYPICAL WOOD FRAMING LATERAL DETAILS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S4.4,TYPICAL WOOD ROOF TRUSS DETAILS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
S4.5,TYPICAL STEEL DETAILS,101 W. 33rd Apartments_STR Details,07/22/22 Permit Revisions
A101,FLOOR PLAN - 1ST,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A102,FLOOR PLAN - 2ND,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A103,FLOOR PLAN - 3RD,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A104,FLOOR PLAN - ROOF,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A150,REFLECTED CEILING PLANS,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A151,REFLECTED CEILING PLANS,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A200,BUILDING ELEVATION - NORTH/WEST,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A201,BUILDING ELEVATION - SOUTH/EAST,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A300,BUILDING SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A301,BUILDING SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A302,BUILDING SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A303,BUILDING SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A400,WALL SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A401,WALL SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A402,WALL SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A410,STAIR SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A411,STAIR SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A412,STAIR SECTIONS,101_W_33rd_St_Shell.rvt,07/22/22 Permit Revisions
A470,UNIT PLANS - STUDIOS - LONG AND SHORT - (TYPE B ADA UNIT - 1ST FLOOR ONLY),101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A471,UNIT PLANS - (TYPE A ADA UNIT - 1ST FLOOR ONLY),101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A472,UNIT PLANS - 1BD - END UNITS,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A500,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,07/22/22 Permit Revisions
A501,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,07/22/22 Permit Revisions
A502,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,07/22/22 Permit Revisions
A503,LARGE SCALE DETAILS,101_W_33rd_St_Details.rte,07/22/22 Permit Revisions
A504,LARGE SCALE DETAILS,101_W_33rd_St_Details.rte,07/22/22 Permit Revisions
A505,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,07/22/22 Permit Revisions
A506,LARGE SCALE DETAILS,101_W_33rd_St_Details_C.rvt,07/22/22 Permit Revisions
A600,SCHEDULES,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A610,WALL -FIRE RATED ASSEMBLY DETAIL -U341,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A611,WALL -FIRE RATED ASSEMBLY DETAIL -U305,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A612,FLOOR -FIRE RATED ASSEMBLY DETAIL -L521,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A613,FLOOR -FIRE RATED ASSEMBLY DETAIL -L521 CONT.,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A614,FIRE STOP DETAILS -FLOOR,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A615,FIRE STOP DETAILS -FLOOR,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A616,FIRE STOP DETAILS -FLOOR,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A617,FIRE STOP DETAILS WALLS,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A751,ADA -TYPE A AND B,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
A800,PARTITION DETAILS - WOOD STUDS,101_W_33rd_St_Units.rvt,07/22/22 Permit Revisions
P100,PLUMBING PLAN TYPICAL UNIT,,08/10/22 Permit Revisions
P101,PLUMBING PLAN 1ST FLOOR,,08/10/22 Permit Revisions
P102,PLUMBING PLAN 2ND FLOOR,,08/10/22 Permit Revisions
P103,PLUMBING PLAN 3RD FLOOR,,08/10/22 Permit Revisions
P104,PLUMBING PLAN ROOF,,08/10/22 Permit Revisions
P200,PLUMBING RISERS,,08/10/22 Permit Revisions
P201,PLUMBING DETAILS,,08/10/22 Permit Revisions
P300,PLUMBING NOTES & SCHEDULES,,08/10/22 Permit Revisions
MEP100,MEP SITE PLAN,,08/10/22 Permit Revisions
MEP101,SITE LIGHTING LEVELS,,08/10/22 Permit Revisions
M100,MECHANICAL PLAN TYPICAL UNIT,,08/10/22 Permit Revisions
M101,MECHANICAL PLAN 1ST FLOOR,,08/10/22 Permit Revisions
M102,MECHANICAL PLAN 2ND FLOOR,,08/10/22 Permit Revisions
M103,MECHANICAL PLAN 3RD FLOOR,,08/10/22 Permit Revisions
M104,MECHANICAL PLAN ROOF,,08/10/22 Permit Revisions
M200,MECHANICAL DETAILS,,08/10/22 Permit Revisions
M300,MECHANICAL NOTES & SCHEDULES,,08/10/22 Permit Revisions
E100,ELECTRICAL POWER PLAN TYPICAL UNIT,,08/10/22 Permit Revisions
E101,ELECTRICAL POWER PLAN 1ST FLOOR,,08/10/22 Permit Revisions
E102,ELECTRICAL POWER PLAN 2ND FLOOR,,08/10/22 Permit Revisions
E103,ELECTRICAL POWER PLAN 3RD FLOOR,,08/10/22 Permit Revisions
E104,ELECTRICAL POWER PLAN ROOF,,08/10/22 Permit Revisions
E120,ELECTRICAL LIGHTING PLAN TYPICAL UNIT,,08/10/22 Permit Revisions
E121,ELECTRICAL EXTERIOR LIGHTING PLAN 1ST FLOOR,,08/10/22 Permit Revisions
E122,ELECTRICAL EXTERIOR LIGHTING PLAN 2ND FLOOR,,08/10/22 Permit Revisions
E122,ELECTRICAL EXTERIOR LIGHTING PLAN 3RD FLOOR,,08/10/22 Permit Revisions
E200,ELECTRICAL RISER & DETAILS,,08/10/22 Permit Revisions
E201,ELECTRICAL PANEL SCHEDULES,,08/10/22 Permit Revisions
E300,ELECTRICAL NOTES AND SCHEDULES,,08/10/22 Permit Revisions

1 Sheet_Number Sheet_Name Sheet_File Sheet_Last_Issue_Date
2 G000 COVER 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
3 G001 CODE & LIFE SAFETY 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
4 S0.0 G002 TYPICAL GENERAL NOTES CODE & LIFE SAFETY 101 W. 33rd Apartments_STR Details 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
5 S0.01 S0.0 STATEMENT OF SPECIAL INSPECTIONS TYPICAL GENERAL NOTES 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
6 S0.1 S0.01 FOUNDATION PLAN STATEMENT OF SPECIAL INSPECTIONS 101_W_33rd_St_Structure.rvt 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
7 S0.1A S0.1 FOUNDATION NOTES AND 3D FOUNDATION PLAN 101_W_33rd_St_Structure.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
8 S0.2 S0.1A FRAMING PLAN - 2ND FLOOR FOUNDATION NOTES AND 3D 101_W_33rd_St_Structure.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
9 S0.3 S0.2 FRAMING PLAN - 3RD FLOOR FRAMING PLAN - 2ND FLOOR 101_W_33rd_St_Structure.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
10 S0.4 S0.3 FRAMING PLAN - ROOF FRAMING PLAN - 3RD FLOOR 101_W_33rd_St_Structure.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
11 S3.0 S0.4 FOUNDATION DETAILS FRAMING PLAN - ROOF 101 W. 33rd Apartments_STR Details 101_W_33rd_St_Structure.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
12 S3.1 S3.0 FOUNDATION DETAILS 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
13 S4.0 S3.1 TYPICAL WOOD FRAMING DETAILS FOUNDATION DETAILS 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
14 S4.1 S4.0 TYPICAL WOOD FRAMING WALL DETAILS TYPICAL WOOD FRAMING DETAILS 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
15 S4.2 S4.1 TYPICAL WOOD FLOOR TRUSS DETAILS TYPICAL WOOD FRAMING WALL DETAILS 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
16 S4.3 S4.2 TYPICAL WOOD FRAMING LATERAL DETAILS TYPICAL WOOD FLOOR TRUSS DETAILS 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
17 S4.4 S4.3 TYPICAL WOOD ROOF TRUSS DETAILS TYPICAL WOOD FRAMING LATERAL DETAILS 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
18 S4.5 S4.4 TYPICAL STEEL DETAILS TYPICAL WOOD ROOF TRUSS DETAILS 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
19 A101 S4.5 FLOOR PLAN - 1ST TYPICAL STEEL DETAILS 101_W_33rd_St_Units.rvt 101 W. 33rd Apartments_STR Details 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
20 A102 A101 FLOOR PLAN - 2ND FLOOR PLAN - 1ST 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
21 A103 A102 FLOOR PLAN - 3RD FLOOR PLAN - 2ND 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
22 A104 A103 FLOOR PLAN - ROOF FLOOR PLAN - 3RD 101_W_33rd_St_Shell.rvt 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
23 A150 A104 REFLECTED CEILING PLANS FLOOR PLAN - ROOF 101_W_33rd_St_Units.rvt 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
24 A200 A150 BUILDING ELEVATION - NORTH/WEST REFLECTED CEILING PLANS 101_W_33rd_St_Shell.rvt 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
25 A201 A151 BUILDING ELEVATION - SOUTH/EAST REFLECTED CEILING PLANS 101_W_33rd_St_Shell.rvt 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
26 A300 A200 BUILDING SECTIONS BUILDING ELEVATION - NORTH/WEST 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
27 A301 A201 BUILDING SECTIONS BUILDING ELEVATION - SOUTH/EAST 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
28 A302 A300 BUILDING SECTIONS 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
29 A303 A301 BUILDING SECTIONS 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
30 A400 A302 WALL SECTIONS BUILDING SECTIONS 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
31 A401 A303 WALL SECTIONS BUILDING SECTIONS 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
32 A402 A400 WALL SECTIONS 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
33 A410 A401 STAIR SECTIONS WALL SECTIONS 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
34 A411 A402 STAIR SECTIONS WALL SECTIONS 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
35 A412 A410 STAIR SECTIONS 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
36 A470 A411 UNIT PLANS - STUDIOS - LONG AND SHORT - (TYPE B ADA UNIT - 1ST FLOOR ONLY) STAIR SECTIONS 101_W_33rd_St_Units.rvt 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
37 A471 A412 UNIT PLANS - (TYPE A ADA UNIT - 1ST FLOOR ONLY) STAIR SECTIONS 101_W_33rd_St_Units.rvt 101_W_33rd_St_Shell.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
38 A472 A470 UNIT PLANS - 1BD - END UNITS UNIT PLANS - STUDIOS - LONG AND SHORT - (TYPE B ADA UNIT - 1ST FLOOR ONLY) 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
39 A500 A471 LARGE SCALE DETAILS UNIT PLANS - (TYPE A ADA UNIT - 1ST FLOOR ONLY) 101_W_33rd_St_Details_C.rvt 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
40 A501 A472 LARGE SCALE DETAILS UNIT PLANS - 1BD - END UNITS 101_W_33rd_St_Details_C.rvt 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
41 A502 A500 LARGE SCALE DETAILS 101_W_33rd_St_Details_C.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
42 A503 A501 LARGE SCALE DETAILS 101_W_33rd_St_Details.rte 101_W_33rd_St_Details_C.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
43 A504 A502 LARGE SCALE DETAILS 101_W_33rd_St_Details.rte 101_W_33rd_St_Details_C.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
44 A505 A503 LARGE SCALE DETAILS 101_W_33rd_St_Details_C.rvt 101_W_33rd_St_Details.rte 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
45 A506 A504 LARGE SCALE DETAILS 101_W_33rd_St_Details_C.rvt 101_W_33rd_St_Details.rte 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
46 A600 A505 SCHEDULES LARGE SCALE DETAILS 101_W_33rd_St_Units.rvt 101_W_33rd_St_Details_C.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
47 A610 A506 WALL -FIRE RATED ASSEMBLY DETAIL -U341 LARGE SCALE DETAILS 101_W_33rd_St_Units.rvt 101_W_33rd_St_Details_C.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
48 A611 A600 WALL -FIRE RATED ASSEMBLY DETAIL -U305 SCHEDULES 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
49 A612 A610 FLOOR -FIRE RATED ASSEMBLY DETAIL -L521 WALL -FIRE RATED ASSEMBLY DETAIL -U341 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
50 A613 A611 FLOOR -FIRE RATED ASSEMBLY DETAIL -L521 CONT. WALL -FIRE RATED ASSEMBLY DETAIL -U305 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
51 A614 A612 FIRE STOP DETAILS -FLOOR FLOOR -FIRE RATED ASSEMBLY DETAIL -L521 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
52 A615 A613 FIRE STOP DETAILS -FLOOR FLOOR -FIRE RATED ASSEMBLY DETAIL -L521 CONT. 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
53 A616 A614 FIRE STOP DETAILS -FLOOR 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
54 A617 A615 FIRE STOP DETAILS – WALLS FIRE STOP DETAILS -FLOOR 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
55 A751 A616 ADA -TYPE A AND B FIRE STOP DETAILS -FLOOR 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
56 A800 A617 PARTITION DETAILS - WOOD STUDS FIRE STOP DETAILS – WALLS 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
57 P100 A751 PLUMBING PLAN TYPICAL UNIT ADA -TYPE A AND B 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
58 P101 A800 PLUMBING PLAN 1ST FLOOR PARTITION DETAILS - WOOD STUDS 101_W_33rd_St_Units.rvt 06/10/22 – Issued for Permit 07/22/22 – Permit Revisions
59 P102 P100 PLUMBING PLAN 2ND FLOOR PLUMBING PLAN TYPICAL UNIT 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
60 P103 P101 PLUMBING PLAN 3RD FLOOR PLUMBING PLAN 1ST FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
61 P104 P102 PLUMBING PLAN ROOF PLUMBING PLAN 2ND FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
62 P200 P103 PLUMBING RISERS PLUMBING PLAN 3RD FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
63 P201 P104 PLUMBING DETAILS PLUMBING PLAN ROOF 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
64 P300 P200 PLUMBING NOTES & SCHEDULES PLUMBING RISERS 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
65 MEP100 P201 MEP SITE PLAN PLUMBING DETAILS 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
66 MEP101 P300 SITE LIGHTING LEVELS PLUMBING NOTES & SCHEDULES 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
67 M100 MEP100 MECHANICAL PLAN TYPICAL UNIT MEP SITE PLAN 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
68 M101 MEP101 MECHANICAL PLAN 1ST FLOOR SITE LIGHTING LEVELS 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
69 M102 M100 MECHANICAL PLAN 2ND FLOOR MECHANICAL PLAN TYPICAL UNIT 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
70 M103 M101 MECHANICAL PLAN 3RD FLOOR MECHANICAL PLAN 1ST FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
71 M104 M102 MECHANICAL PLAN ROOF MECHANICAL PLAN 2ND FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
72 M200 M103 MECHANICAL DETAILS MECHANICAL PLAN 3RD FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
73 M300 M104 MECHANICAL NOTES & SCHEDULES MECHANICAL PLAN ROOF 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
74 E100 M200 ELECTRICAL POWER PLAN TYPICAL UNIT MECHANICAL DETAILS 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
75 E101 M300 ELECTRICAL POWER PLAN 1ST FLOOR MECHANICAL NOTES & SCHEDULES 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
76 E102 E100 ELECTRICAL POWER PLAN 2ND FLOOR ELECTRICAL POWER PLAN TYPICAL UNIT 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
77 E103 E101 ELECTRICAL POWER PLAN 3RD FLOOR ELECTRICAL POWER PLAN 1ST FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
78 E104 E102 ELECTRICAL POWER PLAN ROOF ELECTRICAL POWER PLAN 2ND FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
79 E120 E103 ELECTRICAL LIGHTING PLAN TYPICAL UNIT ELECTRICAL POWER PLAN 3RD FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
80 E121 E104 ELECTRICAL LIGHTING PLAN 1ST FLOOR ELECTRICAL POWER PLAN ROOF 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
81 E122 E120 ELECTRICAL LIGHTING PLAN 2ND & 3RD FLOOR ELECTRICAL LIGHTING PLAN TYPICAL UNIT 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
82 E200 E121 ELECTRICAL RISER & DETAILS ELECTRICAL EXTERIOR LIGHTING PLAN 1ST FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
83 E201 E122 ELECTRICAL PANEL SCHEDULES ELECTRICAL EXTERIOR LIGHTING PLAN 2ND FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
84 E300 E122 ELECTRICAL NOTES AND SCHEDULES ELECTRICAL EXTERIOR LIGHTING PLAN 3RD FLOOR 06/10/22 – Issued for Permit 08/10/22 – Permit Revisions
85 E200 ELECTRICAL RISER & DETAILS 08/10/22 – Permit Revisions
86 E201 ELECTRICAL PANEL SCHEDULES 08/10/22 – Permit Revisions
87 E300 ELECTRICAL NOTES AND SCHEDULES 08/10/22 – Permit Revisions

Binary file not shown.

After

Width:  |  Height:  |  Size: 1.1 MiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 3.3 MiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 1.8 MiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 1.1 MiB

Some files were not shown because too many files have changed in this diff Show More