diff --git a/BIM/OD_Revit_Template - 2020.rte b/BIM/OD_Revit_Template - 2020.rte index f7377ea..82f97ae 100644 Binary files a/BIM/OD_Revit_Template - 2020.rte and b/BIM/OD_Revit_Template - 2020.rte differ diff --git a/Code/Code Information.csv b/Code/Code Information.csv index b3be8bd..fbea366 100644 --- a/Code/Code Information.csv +++ b/Code/Code Information.csv @@ -1,4 +1,4 @@ -column_1,column_2,column_3,column_4,column_5 +Column_1,Column_2,Column_3,Column_4,Column_5 APPLICABLE CODES:,"GENERAL: • BUILDING/DWELLING CODE IBC 2015 & AHJ AMENDMENTS EXISTING: @@ -28,7 +28,7 @@ CHAPTER 5 CLASSIFICATION OF WORK:,NEW,,https://up.codes/viewer/texas/iebc-2015/c ",,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.3, 504.4 NUMBER OF STORIES,"R-2 – TYPE V (SPRINKLERED): • ACTUAL: 3 - • ALLOWED: 3 + • ALLOWED: 4 ",,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#504.4, "506.2 ALLOWABLE AREA DETERMINATION @@ -46,12 +46,11 @@ CHAPTER 5 CLASSIFICATION OF WORK:,NEW,,https://up.codes/viewer/texas/iebc-2015/c • MAXIMUM NUMBER OF STORIES FOR GROUP R WITH NFPA 13R SPRINKLERS, PER SEC. 903.3.1.2.THIS CRITERIA IS MET, SO STORY LIMIT = 4 • THE REVISED ALLOWABLE HEIGHT IS 60 FT. -","ACTUAL +ACTUAL • (ALL FLOORS): 16,826SF - • FLOORS: 3",https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#506.2, -508.3 NONSEPARATED OCCUPANCIES:,,N/A,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.3, -508.4 SEPARATED OCCUPANCIES,YES,N/A,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.4, -SECTION 602 CONSTRUCTION CLASSIFICATION:,TYPE-VB,,https://up.codes/viewer/texas/ibc-2015/chapter/6/types-of-construction#602, + • FLOORS: 3",,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#506.2, +508.3 NONSEPARATED OCCUPANCIES:,N/A,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.3, +508.4 SEPARATED OCCUPANCIES,N/A,,https://up.codes/viewer/texas/ibc-2015/chapter/5/general-building-heights-and-areas#508.4, "TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)","FOR TYPE VB STRUCTURAL FRAME: 0 HR @@ -63,14 +62,19 @@ FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)","FOR TYPE VB ROOF CONSTRUCTION: 0 HR ",,https://up.codes/viewer/texas/ibc-2015/chapter/6/types-of-construction#601, "TABLE 602 -FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE"," FIRE SEPARATION DISTANCE +FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE","TYPE-VB + +FIRE SEPARATION DISTANCE • X < 5C = 1 HR • 5 ≤ X ≤ 10 = 1 HR • 10 ≤ X ≤ 30 = 0 HR • X ≥ 30 = 0 HR",,, 708.3 FIRE-RESISTANCE RATING,CORRIDORS: 1/2HR RATED,,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#708.3, 711.2.4.3 DWELLING UNITS AND SLEEPING UNITS,BETWEEN DWELLING UNITS: 1HR RATED,,https://up.codes/viewer/texas/ibc-2015/chapter/7/fire-and-smoke-protection-features#711.2.4.3, -SECTION 1020 CORRIDORS,CORRIDORS: 1/2HR RATED,SEE SECTION 1021 EGRESS BALCONIES FOR CORRIDOR RATING AT EXTERIOR WALL,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1020, +SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS):,NFPA13R SPRINKLER THROUGHOUT PROJECT (R-2),,https://up.codes/viewer/texas/ibc-2015/chapter/9/fire-protection-systems#903.2.8, +SECTION 1020 CORRIDORS,"CORRIDORS: 1/2HR RATED + +SEE SECTION 1021 EGRESS BALCONIES FOR CORRIDOR RATING AT EXTERIOR WALL",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1020, SECTION 1004 OCCUPANT LOAD,"TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT @@ -92,7 +96,6 @@ CORRIDORS SHALL BE FIRE-RESISTANCE-RATED IN ACCORDANCE WITH TABLE 1020.1. THE CO EXCEPTIONS: CORRIDORS ADJACENT TO THE EXTERIOR WALLS OF BUILDINGS SHALL BE PERMITTED TO HAVE UNPROTECTED OPENINGS ON UNRATED EXTERIOR WALLS WHERE UNRATED WALLS ARE PERMITTED BY TABLE 602 AND UNPROTECTED OPENINGS ARE PERMITTED BY TABLE 705.8.",,https://up.codes/viewer/texas/ibc-2015/chapter/10/means-of-egress#1021.2, -SPRINKLERS (SECTION 903 AUTOMATIC SPRINKLER SYSTEMS):,"YES, NFPA13R SPRINKLER THROUGHOUT PROJECT (R-2)",,https://up.codes/viewer/texas/ibc-2015/chapter/9/fire-protection-systems#903.2.8, 2902.1 MINIMUM NUMBER OF FIXTURES,"CLASSIFICATION & OCCUPANCY: --- diff --git a/Code/Code Information.ods b/Code/Code Information.ods index 022bbac..8da9d13 100644 Binary files a/Code/Code Information.ods and b/Code/Code Information.ods differ