parent
9c9001677f
commit
2931a9fad0
0
Literature/_Uniformat/A10 Foundations/A1010 Standard Foundations/Shallow Foundations/Frost Protected Shallow Foundations ASCE 31 - Structural engineering other technical topics - Eng-Tips.url → AEC Literature/A10 Foundations/A1010 Standard Foundations/Shallow Foundations/Frost Protected Shallow Foundations ASCE 31 - Structural engineering other technical topics - Eng-Tips.url
0
Literature/_Uniformat/A10 Foundations/A1010 Standard Foundations/Shallow Foundations/Frost Protected Shallow Foundations ASCE 31 - Structural engineering other technical topics - Eng-Tips.url → AEC Literature/A10 Foundations/A1010 Standard Foundations/Shallow Foundations/Frost Protected Shallow Foundations ASCE 31 - Structural engineering other technical topics - Eng-Tips.url
0
Literature/06 - Wood, Plastics, and Composites/061800 - Glued-Laminated Construction - CLT/Air_leakages_in_cross_laminated_timber_constructions_28022011_docx_xy7tg.pdf → AEC Literature/B10 Superstructure/B1010 Floor Construction/061800 - Glued-Laminated Construction - CLT/Air_leakages_in_cross_laminated_timber_constructions_28022011_docx_xy7tg.pdf
0
Literature/06 - Wood, Plastics, and Composites/061800 - Glued-Laminated Construction - CLT/Air_leakages_in_cross_laminated_timber_constructions_28022011_docx_xy7tg.pdf → AEC Literature/B10 Superstructure/B1010 Floor Construction/061800 - Glued-Laminated Construction - CLT/Air_leakages_in_cross_laminated_timber_constructions_28022011_docx_xy7tg.pdf
0
Literature/06 - Wood, Plastics, and Composites/061800 - Glued-Laminated Construction - CLT/SHANE-Building-Enclosure-Design-Oakland-WSF-150127.pdf → AEC Literature/B10 Superstructure/B1010 Floor Construction/061800 - Glued-Laminated Construction - CLT/SHANE-Building-Enclosure-Design-Oakland-WSF-150127.pdf
0
Literature/06 - Wood, Plastics, and Composites/061800 - Glued-Laminated Construction - CLT/SHANE-Building-Enclosure-Design-Oakland-WSF-150127.pdf → AEC Literature/B10 Superstructure/B1010 Floor Construction/061800 - Glued-Laminated Construction - CLT/SHANE-Building-Enclosure-Design-Oakland-WSF-150127.pdf
0
Literature/06 - Wood, Plastics, and Composites/061813 - Glued-Laminated Beams/ANSI A190.1-2012 Standard for Wood Products - Structural Glued Laminated Timber.pdf → AEC Literature/B10 Superstructure/B1010 Floor Construction/061813 - Glued-Laminated Beams/ANSI A190.1-2012 Standard for Wood Products - Structural Glued Laminated Timber.pdf
0
Literature/06 - Wood, Plastics, and Composites/061813 - Glued-Laminated Beams/ANSI A190.1-2012 Standard for Wood Products - Structural Glued Laminated Timber.pdf → AEC Literature/B10 Superstructure/B1010 Floor Construction/061813 - Glued-Laminated Beams/ANSI A190.1-2012 Standard for Wood Products - Structural Glued Laminated Timber.pdf
Binary file not shown.
@ -0,0 +1,16 @@ |
||||
|
||||
NFPA 13 Sprinkler System: |
||||
|
||||
- Provide sprinklers in concealed spaces; no draftstopping is required |
||||
- No sprinklers in concealed spaces required if one of the following is met: |
||||
- Firestopping installed to compartmentalize the concealed spaces to max. 160 ft3; provide draftstopping above and in line with dwelling unit and sleeping unit separations per 718.3.2 (may utilize draftstopping at these locations to also work toward compartmentalization) |
||||
- Fill concealed spaces (2-in air gap at top permitted) with noncombustible insulation; provide draftstopping above and in line with dwelling unit and sleeping unit separations per 718.3.2 |
||||
- Other options per NFPA 8.15 |
||||
|
||||
NFPA 13R Sprinkler System: |
||||
|
||||
- No sprinklers required in concealed spaces; provide draftstopping above and in line with dwelling unit and sleeping unit separations per IBC 718.3.2 |
||||
- Provide sprinklers in concealed spaces, no draft stopping is required |
||||
<!--stackedit_data: |
||||
eyJoaXN0b3J5IjpbNjQ0NTkxMzkzXX0= |
||||
--> |
Binary file not shown.
Binary file not shown.
@ -0,0 +1,2 @@ |
||||
[InternetShortcut] |
||||
URL=https://www.woodworks.org/experttip/are-sprinklers-required-in-concealed-spaces-such-as-floor-and-roof-cavities-in-multi-family-wood-frame-buildings/ |
Binary file not shown.
0
Literature/06 - Wood, Plastics, and Composites/061100 - Wood Framing/WFCM Guide - Guide to wood frame construction in high wind areas for 1 and 2 family dwellings.pdf → AEC Literature/B20 Exterior Vertical Enclosures/B2010 Exterior Walls/061100 - Wood Framing/WFCM Guide - Guide to wood frame construction in high wind areas for 1 and 2 family dwellings.pdf
0
Literature/06 - Wood, Plastics, and Composites/061100 - Wood Framing/WFCM Guide - Guide to wood frame construction in high wind areas for 1 and 2 family dwellings.pdf → AEC Literature/B20 Exterior Vertical Enclosures/B2010 Exterior Walls/061100 - Wood Framing/WFCM Guide - Guide to wood frame construction in high wind areas for 1 and 2 family dwellings.pdf
0
Literature/05 - Metals/054100 - Metal Studs/Proper Specification and Installation Recommendations for Nonstructural Wall Framing.pdf → AEC Literature/C10 Interior Construction/C1010 Interior Partitions/054100 - Metal Studs/Proper Specification and Installation Recommendations for Nonstructural Wall Framing.pdf
0
Literature/05 - Metals/054100 - Metal Studs/Proper Specification and Installation Recommendations for Nonstructural Wall Framing.pdf → AEC Literature/C10 Interior Construction/C1010 Interior Partitions/054100 - Metal Studs/Proper Specification and Installation Recommendations for Nonstructural Wall Framing.pdf
0
Literature/05 - Metals/054100 - Metal Studs/Proper Specification and Installation Recommendations for Structural Wall Framing.pdf → AEC Literature/C10 Interior Construction/C1010 Interior Partitions/054100 - Metal Studs/Proper Specification and Installation Recommendations for Structural Wall Framing.pdf
0
Literature/05 - Metals/054100 - Metal Studs/Proper Specification and Installation Recommendations for Structural Wall Framing.pdf → AEC Literature/C10 Interior Construction/C1010 Interior Partitions/054100 - Metal Studs/Proper Specification and Installation Recommendations for Structural Wall Framing.pdf
Binary file not shown.
Binary file not shown.
Some files were not shown because too many files have changed in this diff Show More
Loading…
Reference in new issue